Barrel Signal Assignments
Schematic: schematics\CONASGN.sch.pdf
Page last updated: June 19, 2002
For this two sheet drawing, the write up is presented as an additional column titled 'Description'.
Sheet 1:
Servo motor stage connectors
|
Connector
|
Function
|
Drawing
|
Description |
|
J1
|
TV Filter Stage |
EL-3050
|
Controller #1 A-axis |
|
J2
|
TV Focus Stage |
EL-3051
|
Controller #1 B-axis |
|
J3
|
Spare Stage |
-
|
(not assigned) |
|
J4
|
Spare Stage |
-
|
(not assigned) |
|
J5
|
CCD Focus Stage |
EL-3054
|
Controller #1 E-axis |
|
J6
|
CCD Translation Stage |
EL-3055
|
Controller #1 F-axis |
|
J7
|
Science Filter Wheel Stage |
EL-3056
|
Controller #1 G-axis |
|
J8
|
Spare Stage |
-
|
(not assigned) |
|
J9
|
Manual Paddle |
-
|
(not implemented) |
|
-
|
- |
-
|
- |
|
J11
|
Spare Stage |
-
|
(not assigned) |
|
J12
|
Grating Tilt #3 Stage |
EL-3062
|
Controller #2 B-axis |
|
J13
|
Grating Tilt #4 Stage |
EL-3064
|
Controller #2 C-axis |
|
J14
|
Grating Select Stage |
EL-3066
|
Controller #2 D-axis |
|
J15
|
Slitmask Stage |
EL-3067
|
Controller #2 E-axis |
|
J16
|
Spare Stage |
-
|
(not assigned) |
|
J17
|
Spare Stage |
-
|
(not assigned) |
|
J18
|
Spare Stage |
-
|
(not assigned) |
|
J19
|
Manual Paddle |
-
|
(not implemented) |
Secondary Encoder Connectors
|
Connector
|
Function
|
Drawing
|
Description |
|
J21
|
(Not assigned) |
-
|
- |
|
J22
|
(Not assigned) |
-
|
- |
|
J23
|
(Not assigned) |
-
|
- |
|
J24
|
(Not assigned) |
-
|
- |
|
J25
|
(Not assigned) |
-
|
- |
|
J26
|
(Not assigned) |
-
|
- |
|
J27
|
(Not assigned) |
-
|
- |
|
J28
|
(Not assigned) |
-
|
- |
|
J31
|
(Not assigned) |
-
|
- |
|
J32
|
Grating Tilt #3 Stage |
EL-3063
|
Gurley secondary encoder |
|
J33
|
Grating Tilt #4 Stage |
EL-3065
|
Gurley secondary encoder |
|
J34
|
(Not assigned) |
-
|
- |
|
J35
|
(Not assigned) |
-
|
- |
|
J36
|
(Not assigned) |
-
|
- |
|
J37
|
(Not assigned) |
-
|
- |
|
J38
|
(Not assigned) |
-
|
- |
Galil I/O Expansion
|
Connector
|
Function
|
Drawing
|
Description |
|
J101
|
Opto22 panel #1 |
EL-3034
|
Controller #1 outputs |
|
J102
|
Opto22 panel #2 |
EL-3035
|
Controller #1 inputs |
|
J103
|
Opto22 panel #3 |
EL-3036
|
Controller #1 inputs |
|
J101
|
Opto22 panel #4 |
EL-3037
|
Controller #2 outputs |
|
J102
|
Opto22 panel #5 |
EL-3038
|
Controller #2 inputs |
|
J103
|
Opto22 panel #6 |
EL-3039
|
Controller #2 inputs |
AC Outlets
|
Connector
|
Function
|
Drawing
|
Description |
|
AC1
|
Fans |
EL-3004
|
Barrel cooling fans |
|
AC2
|
TV Controller |
EL-3012
|
Controlled Photometrics power |
|
AC3
|
SCSI-to-Fiber Convertor |
EL-3012
|
Controlled SCSI convertor power |
|
AC4
|
AIA-to-SCSI Convertor |
EL-3012
|
Controlled A2S convertor power |
|
AC5
|
Calibration Lockout Power |
EL-3011
|
Power for interlock relay |
|
-
|
- |
-
|
- |
Solenoid Control Connectors
|
Connector
|
Function
|
Drawing
|
Description |
|
J40
|
Calibration lamps |
EL-3011
|
Lamp power supply control signals (at power supply panel) |
|
J41
|
White LED AC control |
EL-3011
|
LED power supply control signal |
|
J42
|
Slitmask solenoid and limits |
EL-3067
|
Controls pneumatic in/out motion of slitmask stage |
|
J43
|
Grating clamp solenoids and PRM |
EL-3082
|
Clamp control signals and PRM enable line from controller #2 |
|
J44
|
Grating clamp limits (out) |
EL-3082
|
Grating clamp limit wiring from controller #2 to distribution panel at front of instrument |
|
J45
|
Grating clamp limits (in) |
EL-3082
|
Grating clamp limit wiring from distribution panel at front of instrument to Bimba cylinders |
|
J46
|
- |
-
|
- |
|
J47
|
- |
-
|
- |
Miscellaneous Connectors
|
Connector
|
Function
|
Drawing
|
Description |
|
J48
|
Dewar Ion Pump |
EL-3014
|
Control and monitoring of CCD dewar |
|
J49
|
Slitmask |
EL-3067
|
Environment sensor wiring (slotted switches) |
|
J50
|
Over temperature shut down |
EL-3003
|
AC power control signal (kills AC) |
|
J51
|
Air and Coolant |
EL-3005
|
Air pressure and coolant sensor signals |
|
J52
|
Lamps |
EL-3011
|
Lamp power supply control signals (at Galil controller #1) |
|
J53
|
Galil #1 hatch interlocks |
EL-3117
|
Hatch identification signals to controller #1 |
|
JH1 (
|
Cradle hatch interlocks |
EL-3120
|
Hatch/rotation interlocks |
|
J55
|
Vessel Ion Pump |
EL-3014
|
Control and monitoring of CCD coolant vessel |
|
J56
|
Slitmask pushbutton station |
EL-3072
|
Local control of slitmask stage |
|
J57
|
Grating pushbutton station |
EL-3071
|
Local control of grating select stage |
|
J58
|
Filter wheel pushbutton station |
EL-3073
|
Local control of filter wheel stage |
|
J59
|
(Not assigned) |
-
|
- |
|
J60
|
Grating clamp pin |
EL-3082
|
Grating clamp pin switch - activated by clamp #2 |
Slitmask Stage Connectors
|
Connector
|
Function
|
Drawing
|
Sheets | Description |
|
JSLIT1
|
J49 - Slitmask I/O |
EL-3067
|
2, 6, 7 | Optical switch enable and sensor connections from slitmask environment box to controller #2 |
|
JSLIT2
|
J42 - Solenoid control |
EL-3067
|
2, 5, 6, 7 | Bimba cylinder control and limits from controller #2 to slitmask environment box |
|
JSLIT3
|
Bimba and foot retracted limits |
EL-3067
|
2, 5, 6, 7 | Bimba cylinder limit and foot retracted connections from cylinder to slitmask environment box |
|
JSLIT4
|
Misaligned and door signals |
EL-3067
|
2, 4, 6, 7, 9 | Misaligned emitter and detector signals and door closed signal from slitmask environment box to cassette box |
|
JSLIT5
|
Environment signals |
EL-3067
|
2, 4, 6, 7 | Slitmask in place 1 and in place 2 and end of travel signals from sensors to slitmask environment box |
|
JSLIT6
|
Solenoid |
EL-3067
|
2, 5, 7 | Slitmask solenoid control signal via door closed switches, from switches to slitmask environment box |
|
JSLIT7
|
Misaligned |
EL-3067
|
2, 4, 6, 7 | Slitmask misaligned 'comb' wiring from sensor to slitmask environment box |
|
J15
|
Stage cable |
EL-3067
|
3 | Main stage cable from Galil panel #2 to stage interconnect box |
|
JB1
|
Interconnect box input |
EL-3067
|
3 | Interconnect box input cable connection |
|
JB2
|
Motor connector |
EL-3067
|
3, 4 | Motor wiring from interconnect box to JSLIT5 and TB-10 |
|
JB3
|
Limit connector |
EL-3067
|
3 | Stage fiducial and primary limit connector |
|
JB6
|
Motor encoder |
EL-3067
|
3 | Stage motor encoder connector |
|
JMIP1
|
Mask position sensor |
EL-3067
|
4 | Mask in place sensor 1 |
|
JMIP2
|
Mask position sensor |
EL-3067
|
4 | Mask in place sensor 2 |
|
JEOT
|
Mask position sensor |
EL-3067
|
4 | Mask end of travel |
Grating Select Stage
|
Connector
|
Function
|
EL-3066
|
EL-3082
|
Description |
|
JG2
|
Clamp/Motor Interlock |
2
|
3
|
Grating clamp/motor interlock connector - motor can't move with any clamps in the 'in' position |
|
JG3
|
Primary Limits |
3
|
-
|
To forward and reverse primary limit switches from PRM box via TB-12 |
|
JG4
|
Stage Fiducial |
3
|
4
|
To stage fiducial from PRM box via TB-12 |
|
JG5
|
Primary Reference Mark (PRM) |
3
|
4
|
To PRM optical slotted switch from PRM box via TB-12 |
|
JG6
|
Limits, Fiducial, and PRM |
1, 3
|
-
|
Primary limits, Fiducial, and PRM (via fiducial signal line) signals from PRM box to Grating Select stage interconnect box |
|
JG7
|
PRM Control |
3
|
2
|
PRM box input connector for PRM drive signal from J46 on Galil controller #2 |
|
JG43
|
Grating Clamps and Entrance Hatch Solenoid |
-
|
2
|
Input connector on grating solenoid plate. Cable connects to J43 on Galil controller #2 |
|
JG44
|
Grating Clamps and Entrance Hatch Solenoid |
-
|
2, 3, 4
|
Bimba cylinder limit switch output connector on grating solenoid plate. Cable connects to J44 on Galil controller #2 |
|
JG45
|
Grating Clamps and Entrance Hatch Solenoid |
-
|
2, 3
|
Bimba cylinder limit switch input connect on grating solenoid plate. Cable connects to limit switches via TBGRATE |
|
JG46
|
PRM Control |
3, 4
|
4
|
Provides enable signal to PRM optical slotted switch. (Galil controller #2 I/O bit 38) |
|
J14
|
Stage cable |
1, 4
|
-
|
Main stage cable from Galil panel #2 to stage interconnect box |
|
JB1
|
Interconnect box input |
1, 4
|
-
|
Interconnect box input cable connection |
|
JB2
|
Motor connector |
1, 2, 4
|
-
|
Motor wiring from interconnect box to JSLIT5 and TB-10 |
|
JB3
|
Limit connector |
1, 3, 4
|
-
|
Stage fiducial and primary limit connector |
|
JB6
|
Motor encoder |
1, 4
|
-
|
Stage motor encoder connector |
Sheet 2:
Calibration Lamp Connectors
|
Connector
|
Function
|
Drawing EL-3011
|
Description |
|
J52
|
Main cable |
1, 2, 5
|
Switched lamp power connector at Galil #1 |
|
J40
|
Main cable |
1, 2, 5
|
Switched lamp power connector at power supply outlet boxes |
|
J41
|
White LED |
2
|
Switched LED power connector at Galil #1 |
|
JLAMP1
|
AC power input |
3
|
Unswitched AC power source to interlock box |
|
JLAMP2
|
DC power, interlock signal |
3
|
12V DC power for relay inside interlock box and lamps locked out signal |
|
JLAMP3
|
AC to Opto22 panel #1 |
3
|
Switched lamp power connector on interlock box that supplies the switched AC fed to the calibration lamp Opto22 relays |
|
JLAMP4
|
Front end cable |
3
|
Cable from interlock box to front of instrument. This carries interlock signals from Lamp interlock Junction Box (front end) to interlock box (electronics ring) |
|
JLAMP5
|
Interlock box cable |
3
|
Mating connector on Lamp Interlock Junction Box for cable from JLAMP4 |
|
JLAMP6
|
Bypass switch |
3
|
(Not implemented) |
|
JLAMP7
|
Interlock switch |
3
|
Lamp Interlock Junction Box connector for wires from Entrance Hatch Bimba switch |
|
JLAMP8
|
Interlock switch |
3
|
(Not implemented) |
|
JLAMP15
|
White LED |
2
|
Switched LED power connector at LED outlet box |
Orange Circuit AC Power Connectors
|
Connector
|
Function
|
Drawing
|
Description |
|
JPOR1
|
Input |
EL-3003
|
AC power coming into barrel from instrument circuit breaker box |
|
JPOR2
|
Output |
EL-3003
|
Controlled power to orange circuit outlets |
|
JPOR3
|
Control |
EL-3003
|
85° F thermostat and Galil cut off signal input connector |
|
JPOR4
|
Alarm |
EL-3003
|
Alarm - Sonalert- output connector |
Blue Circuit AC Power Connectors
|
Connector
|
Function
|
Drawing
|
Description |
|
JPBL1
|
Input |
EL-3003
|
AC power coming into barrel from instrument circuit breaker box |
|
JPBL2
|
Output |
EL-3003
|
Controlled power to blue circuit outlets |
|
JPBL3
|
Control |
EL-3003
|
85° F thermostat input connector (no external control) |
|
JPBL4
|
Alarm |
EL-3003
|
Alarm - Sonalert- output connector |