Collimator Removal for 
  Recoating
  - Remove 3 cladding panels 
    from back of Deimos to give access to the Counterweight Support Assembly D2215-1.
- Rotate Deimos to a mechanical 
    position angle of 0 or 180 per D0002.
- Tension Counterweight 
    Support Assembly D2215-1 to support Counterweight Assembly D2210-1.
- Remove Locking Dog D2211-6.
- Remove Side B Baffle 
    D2251-1 and Baffle Mount Plate D2250-1.
- Remove Alignment Jig 
    D2355.
- Install Lexan Cover
- Remove Lever D2210-1.

  - Rotate to mechanical 
    position angle of 270 per D0002.
- Apply manual brake and 
    lock rotation.
- Remove Collimator Hatch 
    D6402.
- Attach Spreader Bar D0610-1 
    per D2100 and tension to support collimator 
    weight
- Remove bolts and remove 
    taper pins with slid hammer and fixture.
- Lift collimator and cell 
    out of DEIMOS and lay cell on its back.

  - Pick cell with 4 eye 
    bolts and place on Lifting Spider D2223-1 See 
    General Lifting Plan D2221-1.
 
  - Remove Retainer Segments 
    D2205-1 & -2, Retainers D2206-3 
    and Springs D2206-2.
- Loosen Radial Soft Pad 
    D2202 Detail E.
- Remove Lexan cover.
- Pick Lifting Spider D2223-1 
    and lower assembly onto Installation Tool D2208-1 
    (4-step process).
 
 
   
 
  

  - Remove Hub D2217-B, 
    Liner D2210-4, Delrin Pad D2210-5A, and Flange 
    D2210-5B.
  
 
   
 
  
  - Lift mirror and place 
    in crate per D2232. 
 
  - Reassemble in reverse 
    order.