Last updated: 10-22-99
Project: DEIMOS
Stage: Instrumentation Trolley
ID #: KDTR-001A
Engineer: V. Wallace
Mechanical Description of Stage: AC motor
to move DEIMOS into and out of position.
Electronic Description of Stage:
Required setting accuracy:
Performance requirements and design goals
Component |
Requirements 1 |
Motors:- |
- |
Gearbox:- |
- |
Limits 2:- |
- |
Fiducials:- |
- |
Encoders:- |
- |
Air Cylinders:- |
- |
Air Solenoids:- |
- |
Lock/Clamp/Brake:- |
- |
Interlocks:- |
- |
-
Speed, temperature, accuracies, electrical power, pressurized air,
lubricant, coolant, N2 purge, ...
-
Primary (inner) and secondary (outer) limits. These can be magnetic,
optical, or physical contact
Manufacturer's specifications and limitations
Component |
Maximum Operating Condition |
Safe Ops Condition |
Requirements |
Motors: |
- |
- |
- |
Gearbox: |
- |
- |
- |
Limits: |
- |
- |
- |
Fiducials: |
- |
- |
- |
Encoders: |
- |
- |
- |
Air Cylinders: |
- |
- |
- |
Air Solenoids: |
- |
- |
- |
Lock/Clamp/Brake: |
- |
- |
- |
Final Mechanical Assembly and Testing Results
Tests Performed By:
Motor tuning parameters under different spacial
orientations and environment
Parameter |
|
Neutral Gravity |
Uphill 1 |
Downhill |
Cold |
Cold Uphill |
PID Filter: |
KD: |
- |
- |
- |
- |
- |
KP: |
- |
- |
- |
- |
- |
KI: |
- |
- |
- |
- |
- |
Acceleration (pulses/sec^2): |
- |
- |
- |
- |
- |
- |
Deceleration (pulses/sec^2): |
- |
- |
- |
- |
- |
- |
Speed (pulses/sec): |
- |
- |
- |
- |
- |
- |
Other: |
- |
- |
- |
- |
- |
- |
-
Uphill defined as motor (or driven end of shaft) in lowest position
Motion Parameters
Linear Stage (constrained)
Distance from "home" 1 |
Position |
Motor Counts |
Physical Units |
Time to Reach |
Software Limits: |
Forward |
- |
- |
- |
Reverse |
- |
- |
- |
Primary (inner) Limits: |
Forward |
- |
- |
- |
Reverse |
- |
- |
- |
Secondary (outer) Limits: |
Forward |
- |
- |
- |
Reverse |
- |
- |
- |
Position # |
1 |
- |
- |
- |
2 |
- |
- |
- |
3 |
- |
- |
- |
4 |
- |
- |
- |
5 |
- |
- |
- |
6 |
- |
- |
- |
-
"Coarse" if from optical interupter, "Fine" if from an encoder index
pulse. Home is defined as zero counts.
-
Primary limits signal the controller to stop motion. Secondary limits
cut motor power and require intervention to move out of them."Coarse" if
from optical interupter, "Fine" if from an encoder index pulse. Home is
defined as zero counts.
Resolution of Stage
Encoder |
Counts/Inch |
Counts/Millimeter |
Counts/Degree |
On Motor |
- |
- |
- |
On Stage |
- |
- |
- |
-
Repeatability:
-
Fiducial:
-
Encoder:
-
Air Cylinders:
-
Air Solenoids:
NOTES:
Mechanical Drawing(s) # D6920
Electronic Drawing(s) # EL-3123
Sign conventions are such that a positive motion of the motor turns
the motor in a CW direction as viewed from the drive shaft looking back
into the motor, and will drive the stage towards the forward limit.