| Performance requirements and design goals | |
| Component | Requirements 1 |
|---|---|
| Motors: Galil 50-1000 | 3750 RPM / 205 in-oz peak stall torque |
| Limits 2: Microswitch BZ-2RW822-A2 "soft" + DT-2RV22-A7 "hard" | |
| Fiducials: Opto-interupter TRW #OPB-970-T55 (Optical) | |
| Encoders: Gurley 8335-11250-CB-S-A | |
| Air Cylinders: None | |
| Air Solenoids: None | |
| Lock/Clamp/Brake: None | |
| Interlocks: Lockout during manual installation of new grating (see lockout schedule) |
| Manufacturer's specifications and limitations | |||
| Component | Maximum Operating Condition | Safe Ops Condition | Requirements |
|---|---|---|---|
| Motors: | |||
| Limits: | |||
| Fiducials: | |||
| Encoders: | |||
| Air Cylinders: | |||
| Air Solenoids: | |||
| Lock/Clamp/Brake: |
| Motor tuning parameters under different spacial orientations and environment | ||
| Parameter | Set | |
|---|---|---|
| Motor Type: |
|
|
| PID Filter: | KD: |
|
| KP: |
|
|
| KI: |
|
|
| Acceleration (pulses/sec^2): |
|
|
| Deceleration (pulses/sec^2): |
|
|
| Speed: |
|
|
| Set: CN 1,1 CB 1 CEA=2 |
|
| Rotary Stage (constrained) | ||||
| Distance from "home" | Position | Motor Counts | Gurley Counts | Time to Reach |
|---|---|---|---|---|
| Primary (inner) Limits: | Forward |
|
|
|
| Reverse |
|
|
||
| Secondary (outer) Limits: | Forward |
|
|
|
| Reverse |
|
|
||
| Position # None (any posn available) | 1 |
|
|
|
| 2 |
|
|
||
| 3 |
|
|
||
| 4 |
|
|
||
| 5 |
|
|
||
| 6 |
|
|
||
| 1 revolution | CW |
|
|
|
| CCW |
|
|
||
| Gurley Index Position |
|
|
| Resolution of Stage | |||
| Encoder | Counts/Inch | Counts/Millimeter | Counts/Degree |
|---|---|---|---|
| On Motor |
|
|
|
| On Gurley |
|
Electronic Drawing(s) #EL-3058 and EL-3059
Sign conventions are such that a positive motion of the motor turns the motor in a CW direction as viewed from the drive shaft looking back into the motor, and will drive the stage towards the forward limit.
The Grating Tilt #1 stage uses Controller # 2, amplifier 2A and is connected to the A axis.