•Slider 2 (mirror,
direct imaging)
–X=9 px pk-pk, y=14 px
pk-pk
•Slider 3
(grating)
–X=20 px pk-pk, y=13 px
pk-pk
•Slider 4
(grating)
–X=16 px pk-pk, y=9 px
pk-pk
•Slider 3 was predicted
by FEA to be the worst case
•Marked hysteresis is
present depending on PA rotation direction;
working FC system is needed
•Capture range of FC
system (from actual tests)
–X=26 px pk-pk, y=21 px
pk-pk
•