Last updated: 10-14-99
Project: DEIMOS
Stage: Dewar Shutter
ID #: KDCS-001A
Engineer: D. Cowley
Mechanical Description of Stage:
Electronic Description of Stage:
Required setting accuracy :
Performance requirements and design goals
Component |
Requirements 1 |
Motors: None |
- |
Gearbox: None |
- |
Limits 2: Bimba reed switch MRS-.087-XBL-02 |
Two per cylinder, four total |
Fiducials: None |
- |
Encoders: None |
- |
Air Cylinders: 2 |
Bimba #MRS-025-DXP-UG |
Air Solenoids: 2 |
Skinner #73419AN2NN00M1JO11C2 |
Lock/Clamp/Brake:- |
- |
Interlocks:- |
- |
-
Speed, temperature, accuracies, electrical power, pressurized air,
lubricant, coolant, N2 purge, ...
-
Primary (inner) and secondary (outer) limits. These can be magnetic,
optical, or physical contact
Manufacturer's specifications and limitations
Component |
Maximum Operating Condition |
Safe Ops Condition |
Requirements |
Motors: |
- |
- |
- |
Gearbox: |
- |
- |
- |
Limits: |
- |
- |
- |
Fiducials: |
- |
- |
- |
Encoders: |
- |
- |
- |
Air Cylinders: |
- |
- |
40 PSI |
Air Solenoids: |
- |
- |
40PSI |
Lock/Clamp/Brake: |
- |
- |
- |
Final Mechanical Assembly and Testing Results
Motor tuning parameters under different spacial orientations
and environment
Parameter |
|
Neutral Gravity |
Uphill 1 |
Downhill |
Cold |
Cold Uphill |
PID Filter: |
KP: |
- |
- |
- |
- |
- |
KI: |
- |
- |
- |
- |
- |
KD: |
- |
- |
- |
- |
- |
Acceleration (pulses/sec^2): |
- |
- |
- |
- |
- |
- |
Deceleration (pulses/sec^2): |
- |
- |
- |
- |
- |
- |
Speed (pulses/sec): |
- |
- |
- |
- |
- |
- |
Other: |
- |
- |
- |
- |
- |
- |
-
Uphill defined as motor (or driven end of shaft) in lowest position
Motion Parameters
Linear Stage (constrained)
Distance from "home" 1 |
Position |
Motor Counts |
Physical Units |
Time to Reach |
Software Limits: |
Forward |
- |
- |
- |
Reverse |
- |
- |
- |
Primary (inner) Limits: |
Forward |
- |
- |
- |
Reverse |
- |
- |
- |
Secondary (outer) Limits: |
Forward |
- |
- |
- |
Reverse |
- |
- |
- |
Position # |
IN |
- |
- |
? |
OUT |
- |
- |
? |
3 |
- |
- |
- |
4 |
- |
- |
- |
5 |
- |
- |
- |
6 |
- |
- |
- |
-
"Coarse" if from optical interupter, "Fine" if from an encoder index
pulse. Home is defined as zero counts.
-
Primary limits signal the controller to stop motion. Secondary limits
cut motor power and require intervention to move out of them.
-
Gear reduction function:
-
Backlash:
-
Repeatability:
-
Fiducial:
-
Encoder:
-
Air Cylinders:
-
Air Solenoids:
NOTES:
Mechanical Drawing(s) #D5400
Electronic Drawing(s) #EL-1183, EL-1233
Sign conventions are such that a positive motion of the motor turns
the motor in a CW direction as viewed from the drive shaft looking back
into the motor, and will the drive the stage towards the forward limit.